- Seattle Area:
- Eileen Hennessy
at (206) 296-4787 or (206) 296-4632
Downtown Public Health Center
2124 4th Avenue, 4th Floor
Seattle, WA 98121
- North and East Unincorporated King
County and North and Eastside Suburban Cities:
- Mike Bratcher
at (206) 296-9741 or (206) 296-9791
- 10808 NE 145th St.
Bothell, WA 98011
- Unincorporated South King County,
South King County Suburban Cities:
- Mike Milbach
at (206) 205-1903 or (206) 296-4708
- 1404 Central Ave. S., Suite 101
Kent, WA 98032
This is a guideline to the basic
requirements of a food service facility. Actual requirements are
detailed in the Seattle-King County Food Code. If you desire a
copy of the food code, contact your district office.
- Be sure your
plans are professional quality (to scale and in detail).
- Include the
Plan Review Fee of $239.00.
- The Plan
Review Fee Is Not Refundable.
- Provide the
correct number of plans sets. For Building Departments in
Seattle and Unincorporated King County 4 sets are required.
Incorporated cities vary.
| Checklist
for Food Service |
|
- Provide information on the following
items and return checklist with plans.
- Cover page
- Menu
- Equipment Floor Plan (Elevations of
equipment sections may be required)
- Seating
- Finish Schedule
- Sinks
- Restrooms
- Grease Traps
- You must specify on
plans "Health Department inspection required on
completion of work prior to opening"
- Whenever you remodel or start a new food
service operation, there is a 3-part "plan review"
process you must go through. The first two steps must be
completed before construction begins, and the third step must
be completed before you can open.
- Begin with the Land Use Office where your
business is located (Seattle, King County, or incorporated
cities in King County). Bring professional quality plans drawn
to scale. Seattle, DCLU (Department of Construction and Land
Use) and King County DDES (Department of Development and
Environmental Services) require 4 sets of the plans.
Incorporated cities may vary on the number of plans. To ensure
the correct number to submit, please contact your local city
building department. All cities will not route plans to us.
Please be aware some jurisdictions may not accept or approve
plans until plans have been stamped approved by the Public
Health Department. You will need to make sure the Public
Health Department receives two sets of plans.
The Public Health Department Plan Review Fee is $239.00 for
new construction or conversion to a food service
establishment. For establishments being remodeled, the plan
review fee is $182.00
In a large facility with more than one food service operation
(hotel, grocery, etc.), each operation requires a plan review
and a plan review fee. The fee for the first operation is
$239.00 and $120.00 for each additional operation.
If plans are disapproved and returned for alteration an
additional fee for the reexamination will be charged at the
rate of $72.00 per hour.
The plan review fee is not refundable.
- Once plans are submitted, Land Use for
Seattle and Unincorporated King County will send them on to
the Public Health Department. In the City of Seattle, the
Public Health Department will let you know by letter when the
plans have arrived and advise you how much the Health
Department plan review will cost. In Unincorporated King
County, when the plans are submitted to DDES, the plan review
fee will be charged for both the Building Department and the
Health Department. In other jurisdictions, plans will have to
be routed to and approved by the various building departments
and the Health Department. When plans are submitted to the
Health Department the plan review fee will need to be paid at
the time of submittal.
When the "plan review fee" is received:
The Plans Examiner will review the plans for such items as
type of menu, number of seats, smoking/non smoking sections,
plumbing/sinks, food equipment, restrooms, and types of
wall/floor coverings. Actual requirements are detailed in the
Seattle King County Food Code.
A letter stating "plan approved" or a letter
outlining corrections will be sent after the plans are
reviewed. In the City of Seattle, changes to the plans will
require going back through the Land Use office and paying
another fee.
If construction has begun before the plan review is approved,
the food service operations owner will be charged double the
applicable fees.
- Once the building permit has been issued,
construction can begin, and the application for a food service
operating permit can be made. There are 2 additional
requirements to complete before the plan examiner makes the
pre-operational inspection:
- Purchase an operating
permit.
- Have building and plumbing
permits signed off by local agencies.
Please be aware that planning will be needed
to schedule a pre-operational inspection. Contact the Plans
Examiner in the appropriate area at least 1 week
before you wish to open. There is a penalty for beginning to
operate without approval. The penalty for opening without approval
between April 1 and September 30 is double the annual permit fee.
The penalty for opening without approval between October 1 and
March 31 is double the prorated fee (half-year). The double fee
applies to change of ownership as well as new establishments.
- Sinks
- 3-compartment sink, with a
space for soiled utensils ahead of the first compartment
and a drain board for clean utensils after the 3rd
compartment, or a commercial dishwasher is required. If a
commercial dishwasher is provided, it must be equipped
with a pre-rinse sink or equivalent as needed. The size of
the compartments of the 3-compartment sink or the size of
the dishwasher must be large enough to accommodate the
largest utensils/equipment used in the establishment.
Provide make and model of the dishwasher.
- Handsinks are required in
all food preparation areas. Handsinks must remain
accessible and conveniently located to facilitate all
areas where food is handled and prepped. This may require
more than one handsink per food service. Handsinks must be
equipped with mixing faucets and handsoap and paper
towels.
- Hot water to all handsinks
cannot exceed 120 degrees Fahrenheit at the tap. You may
need to install a tempering valve or a separate hot water
heater to handsinks or boost water at other points, such
as the dishwasher.
- Sufficient food preparation
sinks may be required if raw fruits and vegetables are
washed or if meats are thawed. The food preparation sink
must have an indirect waste drain line.
- Establishments serviced by
the City of Seattle's Drainage and Waste Utility are
required to install a grease-capturing device. If the
device of choice is an "Interceptor" it should
be sized according to the Uniform Plumbing Code Appendix
"H". Call (206) 684-7750 for additional
information.
- A service sink (mop sink) is
required.
- A running water dipper well
for bulk ice cream service (optional).
- Liquor service bars or
taverns must have a 3-compartment sink and a separate
handsink. An approved glass washing machine with a
pre-rinse sink may be substituted for the 3-compartment
sink. Be advised that the food service establishment owner
of bars and taverns shall provide a sink compartment for
disposing of liquid waste in addition to sinks necessary
for cleaning and sanitizing.
- Indicate floor drains in all
areas where floors are subject to wetting.
- Restrooms
- Employee
restrooms are required. Convenient, public restrooms,
accessible without going outdoors, are required with
on-premises consumption of food and beverages. Employees
may use the same restrooms provided to the public. This
excerpt from Appendix Table 29A of the 1997 Seattle King
County Plumbing Code shows the number of fixtures:
| Table
29-A: Minimum Plumbing Fixtures 1,2,3 |
|
For the occupancies
listed below, use 30 square feet (2.29 m2)
per occupant for the minimum number of plumbing
fixtures.
|
| Type
of Building or Occupancy |
Water
Closets
(fixtures per person) |
Lavatories
(fixtures per person) |
Bathtub
or Shower
(fixtures per person) |
|
Group A
|
Male |
Female |
Male |
Female |
|
|
Conference
rooms, dining rooms, drinking establishments, exhibit
rooms, gymnasiums,
lounges, stages
|
1:1-25
2:26-75
3:76-125
4:126-200
5:201-300
6:301-400
|
1:1-25
2:26-75
3:76-125
4:126-200
5:201-300
6:301-400
|
one
per 2 water closets |
|
| |
Over
400, add one fixture for each additional 200 males or
150 females
|
|
|
1The
figures shown are based on one fixture being the minimum
required for the number of persons indicated or any fraction
thereof.
2Any
category not mentioned specifically or about which there are any
questions shall be classified by the building official and
included in the category which it most nearly resembles, based
on the expected use of the plumbing facilities.
3Where
urinals are provided, one water closet less than the number
specified may be provided for each urinal installed, except the
number of water closet in such cases shall not be reduced to
less than one half of the minimum specified. For men's
facilities serving 26 or more persons, not less than one urinal
shall be provided.
- Food
service establishments with twelve (12) seats or less and
employing four (4) or fewer people can provide a single
toilet facility for the employees and patrons. The patrons
access to the restroom can not be through any part of the
food preparation, service, or storage areas.
- Plumbing
- Every
plumbing fixture and all sanitary drainage from a food
service establishment (FSE) must be connected to a public
sewer.
- Use
of an on-site sewage (septic) system is not permitted
(under Title 13 Rules and Regulations No. 3 - "King
County Sewage Regulations") due to the volume and
strength of wastewater produced by the typical FSE, which
requires treatment at a municipal sewage treatment plant.
King County Sewage Review Board Approval may be required.
- For
more information, contact the Eastgate District Public
Health Office at (206) 296-4932.
- Equipment
- Provide
adequate refrigeration and freezer units (walk-in coolers,
reach-in refrigerators, sandwich prep refrigerators,
refrigerated display cases, freezers, etc.). Make and
model of all refrigeration units (catalogue cuts) must be
included.
- Provide
details of all cooking line equipment (deep fryer, stoves,
grills, ovens, woks, steamers, etc.).
- Provide
location of equipment in food service areas (steam tables,
soup pots, refrigerated display cases, etc.).
- Detail
work areas (worktables, stationary cutting blocks,
counter, etc.).
- Show
storage areas and cabinetry.
- Indicate
self service areas with sneeze guards (buffet lines, salad
bars, self service condiments, self service beverage,
etc.).
- Finishes
- Specify
the finish of the floors, walls and ceilings in all areas.
Floors, walls and ceilings must be smooth and easily
cleanable.
- Floor
wall junctions must have a coved base.
- All
wood surfaces (doors, trim, shelves, cabinets, etc.) must
be sealed.
- No
exposed plumbing or wiring.
- All
equipment and cabinetry must be flush mounted to counters,
walls or floors, or be raised/located to allow for
cleaning.
- Ventilation
- Show
mechanical exhaust ventilation systems. Contact the local
building department for specifications.
- Miscellaneous
- All
light fixtures must be shielded.
- Show
employee locker areas or employee dressing rooms.
| District
Offices and Building and Plumbing Contacts |
|
| North
District Office |
10501
Meridian Ave. N.
Seattle, 98133 |
206-296-4838 |
| Central
District Office |
172
20th Ave.
Seattle, 98122 |
206-296-4632 |
| Northshore
District Office |
10808
NE 145th St.
Bothell, 98011 |
206-296-9791 |
| Alder
Square District Office |
1404
Central Ave. S.
Suite 101
Kent, 98032 |
206-296-4666 |
| Plumbing
– King County |
14350
SE Eastgate Way
Bellevue, 98007
(for walk-in only-no mail) or
999 3rd Ave., Suite 700
Seattle, 98104
|
206-296-4928
or
206-296-4727
|
| Plumbing
– Seattle |
710
2nd Ave.
Seattle, 98104
|
206-684-5198 |
| DDES |
900
Oaksdale Ave. SW
Renton, 98055
|
206-296-6600 |
| DCLU |
Dexter
Horton Bldg.
710 2nd Ave.
Seattle, 98104
|
206-684-8850 |
- You must apply for a Health
Department Operating Permit before you open. The completed
permit application and fee must be received before opening or
double the amount of the applicable fee will be charged.
|